Software Vendors & OEMs
Ready to integrate web DICOM PACS Viewer and connectivity solutions
Toolbar > System menu > Settings > Hanging protocol. Possibility to create a new hanging protocols, copy and modify existing hanging protocols or groups settings.
Don’t exit or close the settings window without clicking Save settings. The saved settings are applied after the system restart.
Toolbar > System menu > Settings > Hanging protocol > Add new group to create a new group:
Read more detailed Group conditions descriptions and rules in Tags in conditions page.
Watch video tutorial demonstrating how to create a new group in Hanging protocols settings:
Toolbar > System menu > Settings > Hanging protocol > Add new protocol to create a new protocol:
Read more detailed Study, Instance and Prior study conditions descriptions and rules in Tags in conditions page.
Watch video tutorial demonstrating how to create a new hanging protocol in Hanging protocols settings:
Toolbar > System menu > Settings > Hanging protocol > Enable/disable a group or protocol. Possibility to enable/disable groups or hanging protocols:
Watch video tutorial demonstrating how to enable / disable group of protocols or protocol in Hanging protocols settings:
Toolbar > System menu > Settings > Hanging protocol > Copy / Edit to modify a group:
Read more detailed Group conditions descriptions and rules in Tags in conditions page.
Watch video tutorial demonstrating how to copy and edit a group of protocols in Hanging protocols settings:
Toolbar > System menu > Settings > Hanging protocol > Copy / Edit to modify a protocol:
Read more detailed Study, Instance and Prior study conditions descriptions and rules in Tags in conditions page.
Watch video tutorial demonstrating how to copy and edit a hanging protocol in Hanging protocols settings:
Toolbar > System menu > Settings > Hanging protocol > Remove a group / protocol. Possibility to remove a group of protocols or a protocol:
Watch video tutorial demonstrating how to remove a hanging protocol or a group of protocols in Hanging protocols settings:
Remove button deletes the item. If the group is removed, all the protocols of this group are also deleted.
Read more detailed information about setting the Hanging protocols settings in full User Manual document.
There is a possibility to specify Conditions for Group, Study, Prior study and Instance level. Condition tags can be selected in drop-down list. Values can be numeric or string type:
1 – the series or instance serial number is used in condition instead of values of DICOM tags (0020,0011) or (0020,0013);
2 – check the DICOM standard or see “Tags in modalities” sheet, if the particular tag is applicable for the modality.
Notes:
– group conditions are evaluated until the first group that matches the study is found;
– the DICOM file values from the first image of the first series are used when evaluating conditions;
– PR and KO series are ignored, but having SR series as the first series in CT or other study will apply the SR modality group.
1 – the series or instance serial number is used in condition instead of values of DICOM tags (0020,0011) or (0020,0013);
2 – check the DICOM standard or see “Tags in modalities” sheet, if the particular tag is applicable for the modality.
Notes:
– study conditions are evaluated until the first protocol that matches the study is found in the selected group;
– the DICOM file values from the first image of the first series are used when evaluating conditions;
– PR and KO series are ignored, but having SR series as the first series in CT or other study will apply the protocol for SR modality.
1 – the series or instance serial number is used in condition instead of values of DICOM tags (0020,0011) or (0020,0013);
2 – check the DICOM standard or see “Tags in modalities” sheet, if the particular tag is applicable for the modality.
Notes:
– instance conditions are evaluated until the first image that matches the conditions is found in the study or prior study;